LIQUID BUTIMEN MC-3000

APPLICATION OF LIQUID BUTIMEN MC-3000:

Creation of liquid bitumen-aggregate mixture: mixed at batching plant

  • Mixture had close-graded Aggregate
  • Patch potholes, solve immediately after mixing

Creation of liquid bitumen-aggregate mixture: mixed on the scene

  • Mixture had gap-graded Aggregate
  • Patch potholes, solve immediately after mixing

Surface treatment

  • Single bituminous surface treatment (BST)
  • Multiple bituminous surface treatment

ASSURED SPECIFICATION AND NORM:


       I.            Technical standards
No Testing item Unit Test method Technical requirements

TCVN 8818-1:2011

Experiment on liquid Bitumen
1 Viscosity at 50 mm2/s TCVN 7502 : 2005 3000 ÷ 6000
1a Saybolt furol viscosity (at 82.2℃) s TCVN 8817-2:2011 300 ÷ 600
2 Flash point TCVN 8818-2:2011 ≥ 66
3 Water content % TCVN 8818-3:2011 ≤ 0.2
4 Distillation test
4.1 The liquid content obtained at temperatures relative to the total volume of liquid obtained at 360 ℃:

– Distill to 260 ℃

– Distill to 316 ℃

% TCVN 8818-4:2011  

 

 

 

≤ 15

15 ÷ 75

4.2 The bitumen content obtained after distilling at 360 ℃ % TCVN 8818-4:2011 ≥ 80
Testing on liquid samples obtained after distillation
5 Absolute viscosity at 60 ℃ Pa.s TCVN 8818-5:2011 30 ÷ 60
5a Penetration index at 25℃, 5s, 100g 1/10mm TCVN 7495 : 2005 120 ÷ 150
6 Ductility at 25℃, 5cm/min cm TCVN 7496 : 2005 ≥ 100
7 Solubility in Trichlorethylene % TCVN 7500 : 2005 ≥ 99.0